SPECIFICATIONS
Brand Name : Contec
Hign-concerned Chemical : None
Origin : china
Please "Follow" my store, you will get extra discount for fans.
M8
TECHNICAL SPECIFICATIONS
Multi-parameter Patient Monitor
Monitor ECG, SpO2, NIBP, RESP, TEMP, PR and HR.
AUTHORIZED AGENT
.................................................... .................................................... .................................................... .................................................... ....................
Xuzhou Yongkang Electronic Technology Co., Ltd.
NOTE:The specifications are subject to changes without prior notice.
Tel:+86 516 87892766
Address:44F 8C Building Science and technology Area B Economic development district
Xuzhou,Jiangsu,China Post code: 221001
Fax:+86 516 87892766-606
Email:office@yonker.cn
Website:www.yonker.cn
Quality Standards and Classification
CE, ISO13485
SFDA: Class Ⅱb
Anti-electroshock degree:
ClassⅠequipment
(internal power supply)
TEMP/SpO2/NIBP: BF
ECG/Resp: CF
5 Leads: RA, LA, LL, RL, V
Lead mode: Ⅰ,Ⅱ, Ⅲ, AVR, AVL, AVF, V
Gain: × 1.25mm/mV,2.5mm/mV,
5.0mm/mV, 10mm/mV,
20mm/mV (error ≤ 5%)
Sweep speed: 6.25mm/s,12.5mm/s,25mm/s,
50mm/s (error ≤ ± 10%)
Bandwidth: Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40Hz
Diagnostic 0.05 ~ 130 Hz
Sensitivity: >200 μ V PP
CMRR: ≥ 112dB
Differential Input Impedance: >5M
ohm Electrode Offset Potential: ±300mV
Polarization Voltage: ≥ ± 500mV
Input Impedance: ≥ 5 M
Calibration Voltage: 1mV ± 5%
Measurement range: 0 ~ 100%
Resolution: 1%
Accuracy: 70% ~ 100% ± 2%
40% ~ 69% ± 3%
Display
8”real color LED screen
Environment
Operating environment:
Temperature: 0 ~ 40 ℃
Humidity: ≦ 85 %
Pressure: 86.0 kPa ~ 106.0kPa
Transport and Storage environment:
Temperature: -20 ~ 55 ℃
Humidity: ≦ 93 %
Pressure: 86.0 kPa ~ 106.0kPa
ECG
ST Segment Range: -2.0mV ~ +2.0mV
Accuracy: 0.02mV
ST Segment
SpO2
NIBP
Method: Oscillometry
Measure mode: Manual, Auto, STAT
Measure interval in auto mode:
1~5/10/15/30/60/90/120/180/240/480min
Measure period in STAT mode: 5min
Pulse rate range: 40 ~ 240bpm
Measure & alarm range: Adult
SYS 40 ~ 280mmHg
DAY 10 ~ 220mmHg
MEAN 20 ~ 240mmHg
Pediatric
SYS 40 ~ 220mmHg
DAY 10 ~ 160mmHg
MEAN 20 ~ 170mmHg
Neonatal
SYS 40 ~ 135mmHg
DAY 10 ~ 100mmHg
MEAN 20 ~ 110mmHg
Static pressure measurement
Range: 0 ~ 300mmHg
Accuracy: ± 3mmHg
Resolution: 1mmHg Accuracy:
Max. Mean Error: ± 5mmHg
Max. Standard Deviation: 8mmHg
Overpressure protection:
Adult 300mmHg
Pediatric 240mmHg
Neonatal 150mmHg
Power Requirements
AC: 100~240V, 50Hz/60Hz
DC: Built-in rechargeable battery
Battery: 11.1V 24wh Li-ion battery
2h operating after full charge
5min operating after low battery alarm
Pulse Rate
Measure/alarm range: 20 ~ 300bpm
Resolution: 1bpm
Accuracy: ± 3bpm
TEMP
Channel 2
Measure & alarm range: 0 ~ 50 ℃
Resolution: 0.1℃
Accuracy (on sensor): ±0.1 ℃ (0~50 ℃)
RESP
Method: impedance between RA-LL
Resp Impedance range: 0.3 ~ 3 Ω
Base Impedance range: 200 Ω ~ 4000 Ω
Bandwidth: 0.3 ~ 2.5Hz
Gain: ×0.25, ×0.5, ×1, ×2, ×4
Response rate:
Measurement Range
Adult 0 ~ 120BrPM
Neonatal/Pediatric 0 ~ 150BrPM
Resolution: 1BrPM
Accuracy: 7 ~ 150BrPM ( ± 2BrPM)
0 ~ 6BrPM (unspecified)
Apnea Alarm: 10~40s
Dimension and Weight
Equipment:
210mm×85mm×180mm; 1.40kg
Package:
250mm×175mm×240mm; 3.4kg
Date Storage
Trend diagram/table: 720h
NIBP review: 10000 events
Wave review: 12h
Alarm review: 200 alarm events
Support drug concentration titration analysis
Application Range
Adult/Pediatric/Neonatal/Medicine/Surgery/
Operating Room/ICU/CCU
Yonker is one of the biggest medical and healthcare product manufacturers in China.
Range of product:Patient monitor, Pulse oximeter, Blood pressure monitor,
Thermometer, Fetal Doppler, UV radiation, etc.
The entire production line is medical CE certified and mostly FDA certified.
Standard accessories
NIBP cuff & tube
ECG cable & electrodes
SpO2 sensor
TEMP probe
Lithium-ion battery
Power cable
Operator's manual
Optional accessories
Touch screen
Trolley bracket
Hanging bracket
Monitor recorder
Vehicle-mounted power supply
Main Features
Elegant appearance, clear marks, standard interface, oxyCRG SCREEN, trend graph, big characters, other BED observation, which are convenient for user.
Be applicable for adult, pediatric and neonatal.
Standard parameters of ECG, RESP, NIBP, SpO2 and dual-channel TEMP. IBP, CO2, Built-in printer, curving handle, moving bracket and hanging bracket are optional.
Operation interface with Chinese and English. Finish all operations by keys and knobs.(Optional languages: French, German, Italian, Dutch, Portuguese, Turkish, Spanish, Poland.) design with full built-in module, stable and reliable performance.
8'' color TFT LCD with high-resolution displays patient parameter and waveform, and alarm, bed NO, clock, state and other information provided by the monitor synchronously.
Monitoring contents, scan speed, volume and output contents can be set optionally.
Storage of 480-hour trend data, and review of 40-second holographic waveform.
Storage and review of 72-hour ECG waveform.
Function of NIBP review, storage for up to 2400 NIBP data.
Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability.
Calculation of drug concentration.
Network: connecting with central station, other Bed observation and software updating. Connection mode: wireless and wired.
Built-in rechargeable battery for uninterrupted monitoring.
Print ECG, SpO2, RESP, BP and temperature data with one-key.
Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).
Analysis function for heart rate variability(HRV) (optional)
NIBP:
Method: Oscillometry
Modes: Manual/Auto/Continuous
Auto measure time: Adjustable
Measurement range: 10-270mmHg
ECG:
Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, avR, avL, avF, V
Heart rate range: Adult: 15-300bpm, Pediatric/Neonatal: 15-300bpm
ECG waveform: 2 channels
Accuracy: 1 bpm or 1%
ST segment detection Measurement range:-0.2mv~2.0mv
Alarm: Yes, audible and visual alarm, alarm events review
SPO2:
Measurement range: 0-100%
Accuracy: 70-100%, 2% 0-69%, unspecified
Pulse rate:
Range: 20-254bpm
Accuracy: 3bpm
Breathing:
Method: RA-LL impedance
Range: Adult:0-120rpm; pediatric/neonatal:0-150rpm
Apnea alarm: Yes
Temperature:
Range: 0-50
Apnea: 0.1
Channel: Dual-Channel
EtCO2 (option, not included, you should buy it if you need):
Measurement Mode: Side-stream or mainstream
Measurement range: EtCO2: 0-99mmHg
Accuracy: CO2 concentration
Apnea alarm: YES
IBP (option, not included, you should buy it if you need):
Channel: 2 channels
Pressure transducer: Sensitivity: 5( mV/V/mmHg)
Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Alarm range: -10~300mmHg
Standard parameter & configuration:
3/5 lead ECG, RESP, SpO2, NIMP, TEMP, PR
Optional parameter & configuration (not included):
2-IBP, 12 lead ECG, ETCO2, Printer
Accessory:
Main Unit 1
Power cable 1
NIBP tube 1
ECG cable 1 (5 lead)
ECG Electrodes 10
SPO2 Sensor 1 (adult)
Cuff 1 (adult)
TEMP Skin Sensor 1
Packing list 1
User manual 18 inch screen human /Vet use portable parameter monitor
Item specifics
Standard configuration: ECG, NIBP, SPO2, TEMP, RESP, PR
UPC:
Does not apply
Brand:
Yonker
MPN:
Does Not Apply
Power Adapter: Included
Rechareable lithium battery: Built-in LCD Size:: 8 Inch
Country/Region of Manufacture: China Supply type: Manufacturer
Demension:: 21*18.5*10cm Pacemaker: Yes
Package size:: 26.3*25.5*19 cm Working capability with battery: 2 hours
Package weight:: 3.5 kg Model:
YK-M8
Featured Refinements: Vital Signs Monitor
MUlti-function 5 in 1 Portable 3 channel ECG holter ecg device machine blood pressure monitor with analyzer Clinical Analytical Instruments
Routine functions: ECG, blood pressure, blood oxygen, body temperature, breathing monitoring
Other features:
1.Adopt 5.5-inch high-definition display: 1280*720
2.Powerful operating system, capacitive touch screen operation, easy to use
3.Optional Etco2 and blood sugar functions
4.Small size, can be used in surgical monitoring, bedside monitoring, first aid and other places
5.A variety of placement, fixing methods and hanging, convenient to use in a variety of places
6.Standard TYPE-C interface power supply, which can be powered anytime and anywhere
7.Built-in lithium battery power supply, up to 5-6 hours, with a power bank, can work uninterrupted.
ECG EKG
1, gain selection: 2.5mm/mV;5.0mm/mV;10mm/mV;20mm/mV;
2, lead type: 3 channel;
NIBP blood pressure
1, measurement mode: automatic measurement, continuous measurement, manual measurement three modes;
2, support over voltage protection;
3, static pressure measurement: in the range of 0mmHg (0KPa) ~ 300mmHg (40.0KPa), the measurement error should be 3mmHg (± 0.4kpa);
4, measurement accuracy:the maximum standard error ±5mmHg, the maximum standard deviation 8mmHg;
5, resolution: display resolution should be 0.1kpa (1 mmHg>) ;
SPO2 oxygen saturation
1.Blood pressure saturation measurement range :0% ~ 100%;
2, measurement accuracy: within the range of 90%-100% accuracy should be ±1%;
Pulse frequency
1.Measurement range: the blood oxygen pulse rate ranges from 20bpm to 250bpm, and the measurement error should be ±3bpm;TEMP temperature1, high sensitivity temperature probe;
2, the measurement range :O℃ ~ 50℃: the measurement error does not include the probe is ±0.1℃, including the probe is ±0.2℃.
Product list: