Skip to product information
1 of 6

Vitrine Shoping

7/ 8/10 inch Screen Newborn adult/Vet use portable 6-parameter patient monitor vital signs monitor ECG/NIBP/PR/SPO2/RESP/TEMP

7/ 8/10 inch Screen Newborn adult/Vet use portable 6-parameter patient monitor vital signs monitor ECG/NIBP/PR/SPO2/RESP/TEMP

Regular price R$ 3.096,00 BRL
Regular price R$ 3.719,00 BRL Sale price R$ 3.096,00 BRL
Sale Sold out
Taxes included.
Color

SPECIFICATIONS

Brand Name : Contec

Hign-concerned Chemical : None

Origin : china

Tips 1:

Please "Follow" my store, you will get extra discount for fans.

For most countries, there is no transportation problem. If you buy this product, I will send through two or more packages, but sometimes they can not be delivered on the same day, so please wait for another package, or contact the seller for enquiries.

M8

TECHNICAL SPECIFICATIONS

Multi-parameter Patient Monitor

Monitor ECG, SpO2, NIBP, RESP, TEMP, PR and HR.

AUTHORIZED AGENT

.................................................... .................................................... .................................................... .................................................... ....................

Xuzhou Yongkang Electronic Technology Co., Ltd.

NOTE:The specifications are subject to changes without prior notice.

Tel:+86 516 87892766

Address:44F 8C Building Science and technology Area B Economic development district

Xuzhou,Jiangsu,China Post code: 221001

Fax:+86 516 87892766-606

Email:office@yonker.cn

Website:www.yonker.cn

Quality Standards and Classification

CE, ISO13485

SFDA: Class Ⅱb

Anti-electroshock degree:

ClassⅠequipment

(internal power supply)

TEMP/SpO2/NIBP: BF

ECG/Resp: CF

5 Leads: RA, LA, LL, RL, V

Lead mode: Ⅰ,Ⅱ, Ⅲ, AVR, AVL, AVF, V

Gain: × 1.25mm/mV,2.5mm/mV,

5.0mm/mV, 10mm/mV,

20mm/mV (error ≤ 5%)

Sweep speed: 6.25mm/s,12.5mm/s,25mm/s,

50mm/s (error ≤ ± 10%)

Bandwidth: Surgery 1 ~ 25 Hz

Monitor 0.5 ~ 40Hz

Diagnostic 0.05 ~ 130 Hz

Sensitivity: >200 μ V PP

CMRR: ≥ 112dB

Differential Input Impedance: >5M

ohm Electrode Offset Potential: ±300mV

Polarization Voltage: ≥ ± 500mV

Input Impedance: ≥ 5 M

Calibration Voltage: 1mV ± 5%

Measurement range: 0 ~ 100%

Resolution: 1%

Accuracy: 70% ~ 100% ± 2%

40% ~ 69% ± 3%

Display

8”real color LED screen

Environment

Operating environment:

Temperature: 0 ~ 40 ℃

Humidity: ≦ 85 %

Pressure: 86.0 kPa ~ 106.0kPa

Transport and Storage environment:

Temperature: -20 ~ 55 ℃

Humidity: ≦ 93 %

Pressure: 86.0 kPa ~ 106.0kPa

ECG

ST Segment Range: -2.0mV ~ +2.0mV

Accuracy: 0.02mV

ST Segment

SpO2

NIBP

Method: Oscillometry

Measure mode: Manual, Auto, STAT

Measure interval in auto mode:

1~5/10/15/30/60/90/120/180/240/480min

Measure period in STAT mode: 5min

Pulse rate range: 40 ~ 240bpm

Measure & alarm range: Adult

SYS 40 ~ 280mmHg

DAY 10 ~ 220mmHg

MEAN 20 ~ 240mmHg

Pediatric

SYS 40 ~ 220mmHg

DAY 10 ~ 160mmHg

MEAN 20 ~ 170mmHg

Neonatal

SYS 40 ~ 135mmHg

DAY 10 ~ 100mmHg

MEAN 20 ~ 110mmHg

Static pressure measurement

Range: 0 ~ 300mmHg

Accuracy: ± 3mmHg

Resolution: 1mmHg Accuracy:

Max. Mean Error: ± 5mmHg

Max. Standard Deviation: 8mmHg

Overpressure protection:

Adult 300mmHg

Pediatric 240mmHg

Neonatal 150mmHg

Power Requirements

AC: 100~240V, 50Hz/60Hz

DC: Built-in rechargeable battery

Battery: 11.1V 24wh Li-ion battery

2h operating after full charge

5min operating after low battery alarm

Pulse Rate

Measure/alarm range: 20 ~ 300bpm

Resolution: 1bpm

Accuracy: ± 3bpm

TEMP

Channel 2

Measure & alarm range: 0 ~ 50 ℃

Resolution: 0.1℃

Accuracy (on sensor): ±0.1 ℃ (0~50 ℃)

RESP

Method: impedance between RA-LL

Resp Impedance range: 0.3 ~ 3 Ω

Base Impedance range: 200 Ω ~ 4000 Ω

Bandwidth: 0.3 ~ 2.5Hz

Gain: ×0.25, ×0.5, ×1, ×2, ×4

Response rate:

Measurement Range

Adult 0 ~ 120BrPM

Neonatal/Pediatric 0 ~ 150BrPM

Resolution: 1BrPM

Accuracy: 7 ~ 150BrPM ( ± 2BrPM)

0 ~ 6BrPM (unspecified)

Apnea Alarm: 10~40s

Dimension and Weight

Equipment:

210mm×85mm×180mm; 1.40kg

Package:

250mm×175mm×240mm; 3.4kg

Date Storage

Trend diagram/table: 720h

NIBP review: 10000 events

Wave review: 12h

Alarm review: 200 alarm events

Support drug concentration titration analysis

Application Range

Adult/Pediatric/Neonatal/Medicine/Surgery/

Operating Room/ICU/CCU

Yonker is one of the biggest medical and healthcare product manufacturers in China.

Range of product:Patient monitor, Pulse oximeter, Blood pressure monitor,

Thermometer, Fetal Doppler, UV radiation, etc.

The entire production line is medical CE certified and mostly FDA certified.

Standard accessories

NIBP cuff & tube

ECG cable & electrodes

SpO2 sensor

TEMP probe

Lithium-ion battery

Power cable

Operator's manual

Optional accessories

Touch screen

Trolley bracket

Hanging bracket

Monitor recorder

Vehicle-mounted power supply

Main Features

Elegant appearance, clear marks, standard interface, oxyCRG SCREEN, trend graph, big characters, other BED observation, which are convenient for user.

Be applicable for adult, pediatric and neonatal.

Standard parameters of ECG, RESP, NIBP, SpO2 and dual-channel TEMP. IBP, CO2, Built-in printer, curving handle, moving bracket and hanging bracket are optional.

Operation interface with Chinese and English. Finish all operations by keys and knobs.(Optional languages: French, German, Italian, Dutch, Portuguese, Turkish, Spanish, Poland.) design with full built-in module, stable and reliable performance.

8'' color TFT LCD with high-resolution displays patient parameter and waveform, and alarm, bed NO, clock, state and other information provided by the monitor synchronously.

Monitoring contents, scan speed, volume and output contents can be set optionally.

Storage of 480-hour trend data, and review of 40-second holographic waveform.

Storage and review of 72-hour ECG waveform.

Function of NIBP review, storage for up to 2400 NIBP data.

Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability.

Calculation of drug concentration.

Network: connecting with central station, other Bed observation and software updating. Connection mode: wireless and wired.

Built-in rechargeable battery for uninterrupted monitoring.

Print ECG, SpO2, RESP, BP and temperature data with one-key.

Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).

Analysis function for heart rate variability(HRV) (optional)

NIBP:

Method: Oscillometry

Modes: Manual/Auto/Continuous

Auto measure time: Adjustable

Measurement range: 10-270mmHg

ECG:

Lead mode: 3-lead or 5-lead

Lead selection: I, II, III, avR, avL, avF, V

Heart rate range: Adult: 15-300bpm, Pediatric/Neonatal: 15-300bpm

ECG waveform: 2 channels

Accuracy: 1 bpm or 1%

ST segment detection Measurement range:-0.2mv~2.0mv

Alarm: Yes, audible and visual alarm, alarm events review

SPO2:

Measurement range: 0-100%

Accuracy: 70-100%, 2% 0-69%, unspecified

Pulse rate:

Range: 20-254bpm

Accuracy: 3bpm

Breathing:

Method: RA-LL impedance

Range: Adult:0-120rpm; pediatric/neonatal:0-150rpm

Apnea alarm: Yes

Temperature:

Range: 0-50

Apnea: 0.1

Channel: Dual-Channel

EtCO2 (option, not included, you should buy it if you need):

Measurement Mode: Side-stream or mainstream

Measurement range: EtCO2: 0-99mmHg

Accuracy: CO2 concentration

Apnea alarm: YES

IBP (option, not included, you should buy it if you need):

Channel: 2 channels

Pressure transducer: Sensitivity: 5( mV/V/mmHg)

Transducer sites: ART, PA, CVP, RAP, LAP, ICP

Alarm range: -10~300mmHg

Standard parameter & configuration:

3/5 lead ECG, RESP, SpO2, NIMP, TEMP, PR

Optional parameter & configuration (not included):

2-IBP, 12 lead ECG, ETCO2, Printer

Accessory:

Main Unit 1

Power cable 1

NIBP tube 1

ECG cable 1 (5 lead)

ECG Electrodes 10

SPO2 Sensor 1 (adult)

Cuff 1 (adult)

TEMP Skin Sensor 1

Packing list 1

User manual 18 inch screen human /Vet use portable parameter monitor

Item specifics

Standard configuration: ECG, NIBP, SPO2, TEMP, RESP, PR

UPC:

Does not apply

Brand:

Yonker

MPN:

Does Not Apply

Power Adapter: Included

Rechareable lithium battery: Built-in LCD Size:: 8 Inch

Country/Region of Manufacture: China Supply type: Manufacturer

Demension:: 21*18.5*10cm Pacemaker: Yes

Package size:: 26.3*25.5*19 cm Working capability with battery: 2 hours

Package weight:: 3.5 kg Model:

YK-M8

Featured Refinements: Vital Signs Monitor


MUlti-function 5 in 1 Portable 3 channel ECG holter ecg device machine blood pressure monitor with analyzer Clinical Analytical Instruments

Routine functions: ECG, blood pressure, blood oxygen, body temperature, breathing monitoring
Other features:

1.Adopt 5.5-inch high-definition display: 1280*720
2.Powerful operating system, capacitive touch screen operation, easy to use
3.Optional Etco2 and blood sugar functions
4.Small size, can be used in surgical monitoring, bedside monitoring, first aid and other places
5.A variety of placement, fixing methods and hanging, convenient to use in a variety of places
6.Standard TYPE-C interface power supply, which can be powered anytime and anywhere
7.Built-in lithium battery power supply, up to 5-6 hours, with a power bank, can work uninterrupted.
ECG EKG

1, gain selection: 2.5mm/mV;5.0mm/mV;10mm/mV;20mm/mV;

2, lead type: 3 channel;

NIBP blood pressure

1, measurement mode: automatic measurement, continuous measurement, manual measurement three modes;

2, support over voltage protection;

3, static pressure measurement: in the range of 0mmHg (0KPa) ~ 300mmHg (40.0KPa), the measurement error should be 3mmHg (± 0.4kpa);

4, measurement accuracy:the maximum standard error ±5mmHg, the maximum standard deviation 8mmHg;

5, resolution: display resolution should be 0.1kpa (1 mmHg>) ;

SPO2 oxygen saturation

1.Blood pressure saturation measurement range :0% ~ 100%;

2, measurement accuracy: within the range of 90%-100% accuracy should be ±1%;

Pulse frequency

1.Measurement range: the blood oxygen pulse rate ranges from 20bpm to 250bpm, and the measurement error should be ±3bpm;TEMP temperature1, high sensitivity temperature probe;

2, the measurement range :O℃ ~ 50℃: the measurement error does not include the probe is ±0.1℃, including the probe is ±0.2℃.

Product list:

Multifunctional monitor, adult blood pressure cuff, high precision temperature probe, 3-wire ECG, blood oxygen probe.






View full details